Keysight XP2-class wavelength meters include the 86120 Series.
For the measurement of light sources and signals in wavelength ranges from 700 nm to 1700 nm, the 86120D offers a compelling set of features. This includes ±1.5 ppm accuracy (typical ±1 ppm) and a measurement cycle time of just 0.6 seconds.
| Wavelength range | 700 nm to 1650 nm |
|---|---|
| Best power accuracy | ± 0.6 dB |
| Measurement cycle time | 0.6 s |
| Minimum resolvable line separation | 15 GHz |
| Absolute wavelength accuracy | ± 1 ppm |
Keysight XP2-class wavelength meters provide fast, accurate, and traceable wavelength measurements of dense wavelength division multiplexing (DWDM) signals for calibrating tunable transmitter lasers. Featuring high resolution and repetition rate, our wavelength meters are designed to meet the stringent demands of R&D labs, manufacturing lines, and calibration environments where absolute wavelength accuracy is critical. With wide wavelength coverage and sub-picometer resolution, Keysight wavelength meters ensure compliance with International Telecommunication Union (ITU) grids, minimize drift-related errors, and accelerate tuning and validation tasks. Select the wavelength meter you need based on the wavelength range and absolute wavelength accuracy level you require. Choose one of our popular configurations or configure one specific to your application.
Achieve ultra-fine wavelength resolution with absolute accuracy down to ±0.2 ppm, ideal for tightly spaced ITU channel validation and fine spectral tuning.
Real-time wavelength display and fast measurement speeds enable closed-loop laser tuning and high-throughput manufacturing workflows.
Covers multiple optical wavelength ranges across C, L, and O bands to support diverse applications from optical communications to photonics.
Factory-calibrated to international standards with long-term stability and low drift to provide you confidence in every wavelength measurement.
For the measurement of light sources and signals in wavelength ranges from 700 nm to 1700 nm, the 86120D offers a compelling set of features. This includes ±1.5 ppm accuracy (typical ±1 ppm) and a measurement cycle time of just 0.6 seconds.
Specified wavelength range: 700 – 1650 nm; operating wavelength range 700 – 1700 nm
Innovate at speed with curated support plans and prioritized response and turn-around times.
Get predictable, lease-based subscriptions and full lifecycle management solutions—so you reach your business goals faster.
Experience elevated service as a KeysightCare subscriber to get committed technical response and more.
Ensure your test system performs to specification and meets local and global standards.
Make measurements quickly with in-house, instructor-led training, and eLearning.
Download Keysight software or update your software to the newest version.

The EDU34450A is a bench DMM with dual-display 5.5-digit-resolution digital multimeter with up to 110 readings/s measuring rate for speed-critical tests.

The EDU190A is an anodized metal frame that enables one EDU series instrument to stack on each other. It can be securely attached to the wall or lab bench.

The Keysight DM34460A series 6.5-digit dual-display digital multimeter uses Truevolt technology to perform accurate hardware design validation and debugging.

The Keysight DM34461A 6.5-digit dual-display digital multimeter uses Truevolt technology to perform accurate hardware design validation and debugging.