Keysight phase noise analyzers come in two classes. The PN3-class includes E5045A-E5047A signal source analyzers, and PN7 includes E5055A-E5058A signal source analyzers.
The E5047A PN3 signal source analyzer is a compact, powerful signal source analyzer with frequency range from 5 MHz to 40 GHz.
| Maximum frequency | 40 GHz |
| Maximum offset frequency | 100 MHz |
| Absolute phase noise sensitivity (10 GHz @ 10 kHz offset, Xcorr=1) | -135 |
| Residual phase noise sensitivity (10 GHz @ 10 kHz offset, Xcorr=1) | -150 dBc/Hz |
Detects low-level phase noise and spurious signals with high sensitivity, enabling precise characterization of signal sources and reliable performance of DUTs.
Uses dual independent channels to actively suppress internal noise through cross-correlation, enabling precise and reliable measurement of signal sources with minimal phase noise.
Purpose-built to accurately measure absolute and residual phase noise of both pulsed and non-pulsed signals, enabling comprehensive evaluation of overall system and component-level performance.
Measures amplitude modulation (AM) and baseband noise, both of which can degrade error vector magnitude (EVM) in digitally modulated signals and contribute to overall phase noise performance.
| Maximum frequency | 7 GHz to 54 GHz |
| Maximum offset frequency | 160 MHz to 8 GHz |
| Absolute phase noise sensitivity (10 GHz @ 10 kHz offset, Xcorr=1) | -149 dBc/Hz to -153 |
| Residual phase noise sensitivity (10 GHz @ 10 kHz offset, Xcorr=1) | -187 dBc/Hz to -150 dBc/Hz |
The E5047A PN3 signal source analyzer is a compact, powerful signal source analyzer with frequency range from 5 MHz to 40 GHz.
The Keysight E5047A PN3 signal source analyzer comprises a two-channel cross-correlation system with two programmable low noise DC supplies with up to 15 V and 550 mA current capability. The unit also offers three low noise tuning voltages for -5 to +22 voltage range.
| The E5047A PN3 signal source analyzer enables you to: | Measure absolute and residual (additive) phase noise, pulsed and non-pulsed. |
| Perform two-channel 100 MHz fast Fourier transform (FFT) analysis. | Use transient measurements on frequency, phase, or amplitude versus time. |
| Streamline testing efficiency with an intuitive graphic user interface (GUI), API library, and powerful SCPI command language set. | Evaluate signal sources ranging from CVHF to microwave frequencies such as crystal oscillators, PLL synthesizers, clocks, and more. |
Innovate at speed with curated support plans and prioritized response and turn-around times.
Get predictable, lease-based subscriptions and full lifecycle management solutions—so you reach your business goals faster.
Experience elevated service as a KeysightCare subscriber to get committed technical response and more.
Ensure your test system performs to specification and meets local and global standards.
Make measurements quickly with in-house, instructor-led training, and eLearning.
Download Keysight software or update your software to the newest version.

The EDU34450A is a bench DMM with dual-display 5.5-digit-resolution digital multimeter with up to 110 readings/s measuring rate for speed-critical tests.

The EDU190A is an anodized metal frame that enables one EDU series instrument to stack on each other. It can be securely attached to the wall or lab bench.

The Keysight DM34460A series 6.5-digit dual-display digital multimeter uses Truevolt technology to perform accurate hardware design validation and debugging.