Protocol and Functional testing at millimeter-wave and sub-6 GHz frequencies.
| Maximum angles of arrival | 3 |
| Frequency range | 600 MHz to 8,000 MHz, 22 GHz to 50 GHz |
| Measurement type | Direct far field (DFF) |
| Maximum DUT weight | 5 kg |
| Range length | 1.06 m |
| Use cases | Protocol Verification, Protocol Acceptance, Functional, Performance |
Achieve high measurement throughput with optimized multi-probe layouts designed for rapid beam acquisition and minimal test time.
Evaluate complex beamforming behavior with support for multi-beam, multi-angle, and dynamic beam tracking in realistic OTA environments.
Ensure repeatable results with low path loss design, stable chamber environments, and precise probe positioning.
Accelerate validation cycles with fast switching, parallel measurements, and automated test execution.
| Maximum angles of arrival | Frequency range |
| 600 MHz to 8,000 MHz, 22 GHz to 50 GHz, 24 GHz to 50 GHz | Measurement type |
| Direct far field (DFF) | Maximum DUT weight |
| 5 kg to 12 kg | Range length |
| 1 m to 1.06 m | Protocol Verification, Protocol Acceptance, Functional, Performance, MIMO Performance, RRM 2AoA More… |
Protocol and Functional testing at millimeter-wave and sub-6 GHz frequencies.
Keysight’s F9642A 2D Multi-Probe Anechoic Chamber (MPAC) Pro is a shielded anechoic chamber for protocol and functional testing of FR2 frequencies with direct far-field capability and FR1 4X4 MIMO throughput capability supporting extreme temperature control and thermal imaging.
Innovate at speed with curated support plans and prioritized response and turn-around times.
Get predictable, lease-based subscriptions and full lifecycle management solutions—so you reach your business goals faster.
Experience elevated service as a KeysightCare subscriber to get committed technical response and more.
Ensure your test system performs to specification and meets local and global standards.
Make measurements quickly with in-house, instructor-led training, and eLearning.
Download Keysight software or update your software to the newest version.

The EDU34450A is a bench DMM with dual-display 5.5-digit-resolution digital multimeter with up to 110 readings/s measuring rate for speed-critical tests.

The EDU190A is an anodized metal frame that enables one EDU series instrument to stack on each other. It can be securely attached to the wall or lab bench.

The Keysight DM34460A series 6.5-digit dual-display digital multimeter uses Truevolt technology to perform accurate hardware design validation and debugging.

The Keysight DM34461A 6.5-digit dual-display digital multimeter uses Truevolt technology to perform accurate hardware design validation and debugging.