Provides 28 GHz bandwidth in a replaceable tip form factor; ZIF tips can be left on the DUT as the probe head is moved.
C diff = 32 fF, C se = 48 fF
Provides 28 GHz bandwidth in a replaceable tip form factor; ZIF tips can be left on the DUT as the probe head is moved.
Provides 28 GHz bandwidth in a replaceable tip form factor; ZIF tips can be left on the DUT as the probe head is moved.
Provides 28 GHz bandwidth in a replaceable tip form factor; ZIF tips can be left on the DUT as the probe head is moved.
28 GHz (typical)
| Tr = 20.9 psec (10%-90%, probe only with N2803A) |
1.6 Vpp. ±0.8 V(HD2&3, <-38dB), 2.5 Vpp, ±1.25 V (HD2&3 <-34dB) (with N5440A 450 Ω ZIF tip)*
| 0.8 Vpp. ±0.4 V(HD2&3, <-38dB), 1.6 Vpp, ±0.8 V (HD2&3 <-34dB) (with N5447A 200 Ω ZIF tip)* | Note: HD (Harmonic distortion) <-38 dB is standard; < -34dB wider input range with slightly increased distortion |
| The N5439A ZIF probe head provides 28 GHz bandwidth in an economical replaceable tip form factor. Because of their extremely low loading, the ZIF tips can be left on the DUT as the probe head is moved from one probing site to the next. Order N5440A (450 Ω ceramic), N5447A (200 Ω ceramic) or the new N2838A (450 Ω PC board) for a set of 5 ZIF tips with plastic sporks to aid in soldering the tips to your DUT. The N2838A PC board ZIF tip increased the robustness of the ZIP tip significantly while maintaining the bandwidth performance up to 25 GHz when used in conjunction with the N2803A and N5439A. The N5439A does not include any ZIF probe tips. Variable spacing is from 5 mil – 80 mil (or 0.127 mm – 2 mm). For hands-free operation, use the N2787A 3D probe positioner. It is compatible with all InfiniiMax III probe amplifiers. |
View Options and Upgrades
| See Buy or Rent Options |
Innovate at speed with curated support plans and prioritized response and turn-around times.
Get predictable, lease-based subscriptions and full lifecycle management solutions—so you reach your business goals faster.
Experience elevated service as a KeysightCare subscriber to get committed technical response and more.
Ensure your test system performs to specification and meets local and global standards.
Make measurements quickly with in-house, instructor-led training, and eLearning.
Download Keysight software or update your software to the newest version.

The EDU34450A is a bench DMM with dual-display 5.5-digit-resolution digital multimeter with up to 110 readings/s measuring rate for speed-critical tests.

The EDU190A is an anodized metal frame that enables one EDU series instrument to stack on each other. It can be securely attached to the wall or lab bench.

The Keysight DM34460A series 6.5-digit dual-display digital multimeter uses Truevolt technology to perform accurate hardware design validation and debugging.