The InfiniiMax III probing system provides the highest bandwidth and incredibly low loading to allow for a completely new level of signal fidelity and accuracy.
DC input resistance: R diff = 100 kΩ ±2%, R se = 50 kΩ ±2%
The InfiniiMax III probing system provides the highest bandwidth and incredibly low loading to allow for a completely new level of signal fidelity and accuracy.
20 GHz high-performance probe amplifier for measuring differential and single-ended signals
The InfiniiMax III probing system provides the highest bandwidth and incredibly low loading to allow for a completely new level of signal fidelity and accuracy.
20 GHz
| Tr = 27.1 psec |
DC attenuation ratio: 6:1 (3:1 with 200 Ω ZIF tip)
| Input voltage range: 1.6 Vpp (0.8 Vpp with 200 Ω ZIF tip) | Input common mode range: ±12 V at DC to 250 Hz, ±2.5 V at >250 Hz (±6 V at DC to 250 Hz, ±1.25 V at >250 Hz with 200 Ω ZIF tip) |
| Offset range: ±16 V when probing a single-ended signal |
N5445A 30 GHz Browser Probe Head
| N5444A 30 GHz 2.92/3.4 mm SMA Probe Head | N5439A 28 GHz ZIF probe Head |
| MX0109A 26 GHz Solder-in Probe Head |
UXR 3.5mm oscilloscope
| UXR 1&1.85mm oscilloscope with N2852A adapter | 90000X, Q, V, Z-series oscilloscopes |
| The InfiniiMax III probing system provides the highest bandwidth and incredibly low loading to allow for a completely new level of signal fidelity and accuracy. Four different InfiniiMax III probe amplifiers ranging from 16 GHz to 30 GHz are available for matching your probing solution to your performance and budget requirements. A proprietary 200 GHz fT InP (indium phosphide) IC process with backside ground vias and novel thick film technology is utilized for the InfiniiMax III probe system to accommodate your highest performance needs and is unmatched by any product in the market. | Key Features |
| Full 20 GHz to the probe tip. | Industry’s lowest probe and scope system noise. |
| Industry’s highest fidelity and accuracy due to bandwidth and extremely low loading. | Probe amplifiers loaded with measured s-parameters for more accurate response correction. |
| Probe bandwidth upgradable. | Variety of probe heads for different use models with maximum usability. |
Innovate at speed with curated support plans and prioritized response and turn-around times.
Get predictable, lease-based subscriptions and full lifecycle management solutions—so you reach your business goals faster.
Experience elevated service as a KeysightCare subscriber to get committed technical response and more.
Ensure your test system performs to specification and meets local and global standards.
Make measurements quickly with in-house, instructor-led training, and eLearning.
Download Keysight software or update your software to the newest version.

The EDU34450A is a bench DMM with dual-display 5.5-digit-resolution digital multimeter with up to 110 readings/s measuring rate for speed-critical tests.

The EDU190A is an anodized metal frame that enables one EDU series instrument to stack on each other. It can be securely attached to the wall or lab bench.

The Keysight DM34460A series 6.5-digit dual-display digital multimeter uses Truevolt technology to perform accurate hardware design validation and debugging.

The Keysight DM34461A 6.5-digit dual-display digital multimeter uses Truevolt technology to perform accurate hardware design validation and debugging.