SX2-class Sampling Oscilloscope, 58 GHz Maximum optical bandwidth, Multimode only, Dual Optical Channel

The N1096 multimode DCA-M supports the high-speed demands of AI-driven data centers, offering 224 Gbps or 112 GBd PAM4 measurement capability for multimode (MM) short-reach applications for next-generation AI infrastructure.

Fiber modeMultimode only
Intrinsic jitter< 200 fs rms
Electrical channels0
Optical channels2
Maximum electrical bandwidthN/A
Maximum optical bandwidth58 GHz
View Brochure

Accelerate 1.6T transceiver production and reliability

Fixed configuration sampling oscilloscopes offer cost-optimized optical and electrical measurements in a compact form factor, ideally suited for manufacturing tests. They provide the same precision measurements as our modular sampling oscilloscopes with bandwidth up to 60 GHz optical and 50 GHz electrical. Fixed configuration sampling oscilloscopes form a complete manufacturing test solution when paired with automation software to optimize test throughput and ensure device interoperability and reliability. Keysight fixed configuration sampling oscilloscopes help you efficiently scale optical transceiver testing with a streamlined test setup for maximum efficiency. Choose one of our popular configurations or configure one specific to your application.

Small form factor

Integrate multiple optical and electrical inputs, clock recovery, and precision time-base features in a compact unit to ensure signal integrity and save space.

Manufacturing test optimized

With support for fully automated operations, fixed configuration sampling oscilloscopes enable high-performance and high-throughput manufacturing test operations.

Precision and sensitivity

Extremely low noise and jitter provide the measurement margin needed to maximize manufacturing yield and ensure optimal device reliability.

Low power consumption

These oscilloscopes require less power than benchtop models — a critical feature for continuous manufacturing test environments. 

The N1096 multimode DCA-M supports the high-speed demands of AI-driven data centers, offering 224 Gbps or 112 GBd PAM4 measurement capability for multimode (MM) short-reach applications for next-generation AI infrastructure.

Fixed Configuration

Compact signal analysis for manufacturing validation

Keysight SX2-class fixed configuration sampling oscilloscopes include the DCA-M Series.

Highlights

Optimize transceiver performance and scale production testing with the N1093A 224 Gb/s signle channel optical sampling oscilloscope. One weak link in an AI data center can slow the entire network. Maximize network reliability with accurate optical measurements using a low-noise, low-jitter, and high-optical-sensitivity oscilloscope. Scale high-volume manufacturing testing with FlexOTO optimization software which lessens program setup and oscilloscope idle time.

  • Optical bandwidth 60 GHz with SIRC (System Impulse Response Correction) enabled
  • High sensitivity with <20 uW noise
  • Accurate high data-rate analysis with <90 fs jitter (option PTB)
  • Up to 120 GBd Integrated clock recovery available (option CDR and CRX)
  • Fast throughput with high 250 kHz sample rate
  • Small footprint from compact design

What’s included:

USB cable (for connection to DCA-X mainframe or user-supplied PC)

  • Power cord
  • Instrument cover
  • Optimize transceiver performance and scale production testing with the N1093A 224 Gb/s signle channel optical sampling oscilloscope. One weak link in an AI data center can slow the entire network. Maximize network reliability with accurate optical measurements using a low-noise, low-jitter, and high-optical-sensitivity oscilloscope. Scale high-volume manufacturing testing with FlexOTO optimization software which lessens program setup and oscilloscope idle time.
  • Optical bandwidth 60 GHz with SIRC (System Impulse Response Correction) enabled
  • High sensitivity with <20 uW noise
  • Accurate high data-rate analysis with <90 fs jitter (option PTB)
  • Up to 120 GBd Integrated clock recovery available (option CDR and CRX)
  • Fast throughput with high 250 kHz sample rate
  • Small footprint from compact design
  • USB cable (for connection to DCA-X mainframe or user-supplied PC)
  • Power cord
  • Instrument cover
  • The N1096B 224 Gb/s multimode dual channel optical DCA-M sampling oscilloscope delivers leading-edge technology to optimize 1.6T multimode transceiver performance and scale production testing to meet the growing demands of AI data centers. It maximizes network reliability through highly accurate optical measurements, enabled by a low-noise, low-jitter architecture and exceptional optical sensitivity—ensuring confident validation from design through high-volume manufacturing.
  • 780 to 1100 nm, multimode.
  • Optical bandwidth 58 GHz with System Impulse Response Correction (SIRC) enabled.
  • High sensitivity with ≤35 uW noise.
  • Accurate high data-rate analysis with <200 fs jitter (option LOJ).
  • Fast throughput with a high 250 kHz sample rate.
  • Small footprint through compact design.
  • USB cable (for connection to DCA-X mainframe or user-supplied PC).
  • Power cord.
  • Instrument cover.

Service and Support

KeysightCare

Innovate at speed with curated support plans and prioritized response and turn-around times.

Financial Alternatives

Get predictable, lease-based subscriptions and full lifecycle management solutions—so you reach your business goals faster.

Keysight Support Portal

Experience elevated service as a KeysightCare subscriber to get committed technical response and more.

Calibration

Ensure your test system performs to specification and meets local and global standards.

Education

Make measurements quickly with in-house, instructor-led training, and eLearning.

Software Download Center

Download Keysight software or update your software to the newest version.

Related Products

Request for quote

LET’S WORK TOGETHER

Request a quote

A few details to help us understand your requirements.

Your details

Project location

What can we help with?

Your details are only used to respond to your enquiry.