Collection:

Multiband Vector Transceivers

Wideband RF transceiver testing

Keysight VT5-class multiband RF vector transceivers include the S9100A-S9130A

Model:

S9110A

N/A

VT5-class Vector Transceiver, for 5G multiband testing

The S9110A is a multiband transceiver system for 5G and NTN / satellite communication non-signaling measurements. Working with multiple Keysight remote radio heads (RRH), the S9110A system supports measurements from 10 GHz to 32 GHz or 22.7 GHz to 49.2 GHz, as well as sub-6 GHz FR1 capability.

Wireless standard FR1, FR2, NTN
Maximum frequency 49.2 GHz
Maximum bandwidth 1.2 GHz

Scalable tools for complete 5G and ORAN base station performance testing

Keysight cellular base station solutions validate 5G NR, LTE, and ORAN gNB performance through development. They emulate realistic radio environments with fading, beamforming, and load testing across sub-6 GHz (FR1), mmWave (FR2), and non-terrestrial networks. Offering high-performance transceivers with scalable RF channels, wide bandwidth, and real-time fading. Software enables automated KPI testing, MIMO/Massive MIMO channel modeling, and OTA validation. For lab and production, solutions support remote heads, cloud control, and standards-aligned automation (open APIs). Request a quote for one of our popular configurations today. Need help selecting? Check out the resources below.

Massive MIMO beamforming

Validate beam management, tracking, and precoding algorithms with full-stack, OTA testing of active antenna systems.

Real-time channel fading emulation

Simulate dynamic MIMO and massive MIMO channel conditions using enhanced fading profiles with configurations up to 64×64.

High-frequency OTA testing

Conduct OTA testing at mmWave bands using calibrated setups for conformance and performance characterization.

Carrier-grade network environment modeling

Simulate network conditions using carrier-calibrated channel models to evaluate performance under realistic deployment scenarios.

Workflow stage Development, Acceptance, Interoperability, Deployment, Design validation, Manufacture test
Test domain RF, Performance, Non-signaling PXIe performance
Technology 5G NR, LTE, NTN, RedCap, 6G

The S9110A is a multiband transceiver system for 5G and NTN / satellite communication non-signaling measurements. Working with multiple Keysight remote radio heads (RRH), the S9110A system supports measurements from 10 GHz to 32 GHz or 22.7 GHz to 49.2 GHz, as well as sub-6 GHz FR1 capability.

Applications: High-volume test of 5G NR or NTN/Satellite communication network equipment and radio components

5G NR base station transceiver systems

5G NR components, including remote radio heads (RRH), distributed units (DU), active antenna arrays, amplifiers, chipsets NTN devices, including terminal, user devices, spaceborne platform, gateway
Power, SEM, ACLR, EVM and more measurements using familiar and industry proven application software (N9085EM0E 5G NR, and N9054EM0E/N9054EM1E VMA Measurement Application)

Functionality

Wideband signal generation and analysis of 5G NR (3GPP Release 15 and higher) waveforms in both: FR1 (380 MHz to 6 GHz) and FR2 (22.7 GHz to 49.2 GHz) or NTN (10 GHz to 32 GHz)

Features “OTA-friendly” expandable architecture: avoids high losses from switching and long cable runs, supports one or two remote heads and polarizations, and multiple Tx/Rx channels

Measurement applications and software

The S9110A system includes 5G NR Non-Signaling Waveform and Measurement Application as default (licensed as Y9085EM0E or N9085EM0E, depending on your configuration choice)

Additional recommended software: N9054EM0E Vector Modulation Analysis Digital Demodulation Measurement Application, N9054EM1E Vector Modulation Analysis Custom OFDM Application, N7608EMBC Signal Studio Pro for Custom Modulation, N7631EMBC Signal Studio Pro for 5G NR, N7608EMBC for custom IQ and OFDM, 89600 VSA software, and KS8400A Test Automation Platform The Keysight S9110A 5G Multiband Vector Transceiver with one or two transceivers covers FR1 (380 MHz to 6 GHz) along with one or two mmWave/uWave transceivers that covers FR2 (22.7 GHz to 49.2 GHz), or NTN (10 GHz to 32 GHz).

Benefits

Lower Cost of Test with reduced footprint vs. benchtop instruments and extremely high test-throughput (“cloud ready”)

  • OTA readiness saves space and cost with single bi-directional remote heads, with in-head switching for 2 polarizations, across all 10 GHz to 32 GHz (M1742A) or 22.7 GHz to 49.2 GHz (M1749B) bands, delivering best Power and EVM at chamber
  • Manufacturing Effectiveness: 1.2 GHz bandwidth, with low EVM and ACLR, operates as single instrument (includes: switching, heads, API, measurements), easy automation with calibrated system accuracy that reduces rework and false verdicts
  • Supports both FR1 and FR2/NTN measurements in the same system without the need to re-cable the test setup

Service and Support

KeysightCare

Innovate at speed with curated support plans and prioritized response and turn-around times.

Financial Alternatives

Get predictable, lease-based subscriptions and full lifecycle management solutions—so you reach your business goals faster.

Keysight Support Portal

Experience elevated service as a KeysightCare subscriber to get committed technical response and more.

Calibration

Ensure your test system performs to specification and meets local and global standards.

Education

Make measurements quickly with in-house, instructor-led training, and eLearning.

Software Download Center

Download Keysight software or update your software to the newest version.

Related Products

Request for quote